1. What
Is Slump Cone Test.
Slump cone test is a simple site test carried out to determine the workability
and consistency of fresh concrete.
Each sample shall be Remixed before carrying out the test.
2. Why
do I need a Slump cone test.
Concrete slump test measure to fresh
concrete workability and consistency. Sometimes concrete too wet or too
dry which can be unfavourable for the specific work.
3. Sampling
for Slump Test. As
per IS CODE 1199-Part-1
Fresh
concrete sample shall be collected from a moving stream during discharge from :Sample shall be tested immediately.
|
1. Mixer
|
2. Transit mixer |
3. Pump Line |
4. Boom Pressure |
4. Tolerance of Tamping Rod. As per IS CODE 1199-Part-2 Clause. 4.3.2.2
The tamping rod shall be checked periodically to ensure compliance|
|
|
|
|
5. 5. Tolerance of Slump Cone Size. As per IS CODE 1199-Part-2 Clause. 4.3.2.1
|
a)
Diameter of base
|
200 ± 2 MM |
|
b)
Diameter of top
|
100 ± 2 MM |
|
c)
Height
|
300 ± 2 MM |
d)
Thickness of mould at least 1.6
MM
e) Mould shall be
metallic, non-absorbent, with smooth internal surface and free from dents.
6.
6. Filling slump cone As per IS CODE 1199-Part-2 Clause. 4.3.3
Slump cone shall be filled in 3 equal layers.
Using the steel tamping rod to tamp
the concrete.
1. Bottom layer
2. Middle layer
3. Top layer
Each layer shall be tamped 25 times using tamping rod.
Mould lift vertically In 5 second ±
2 second
Finish the test within 180 second ( 3 Minutes )
Record the Slump value Measured to
the nearest 5MM
7. Test Result As per IS CODE 1199-Part-2 Clause. 4.3.4
Only True slump meets acceptance criteria as per IS 1199:2018|
|
|
|
|
|
Invalid Test |
|
|
|
Invalid Test |
|
Note
:- Specified slump in mix design and
Slump value as per Project specifications.
Recommended ranges as per IS 456.
In case of shear or collapse slump, a fresh
sample shall be taken and test repeated.
8. 8. WORKABILITY OF CONCRETE As per IS CODE 456 Clause no.7.1 Page-17
|
WORKABILITY OF
CONCRETE |
||||
|
Placing Conditions |
Degree of
Workability |
Slump Value ( MM ) |
Remarks |
|
|
Blinding concrete: |
Very Low |
See 7.1.1 |
By pavers Machine |
|
|
Mass concrete, |
Low |
25 – 75 MM |
Mass concreting work |
|
|
Heavily reinforced slabs, beams, walls &
columns. |
Medium |
50 – 100 MM |
Low rise
Building by pump |
|
|
Trench fill, in-situ piling, tremie concrete,
Drain , wall , slab |
75 – 100 MM |
|||
|
Slab,beam,wall, column |
High |
100 – 150 MM |
High Rise Building |
|
|
Situ Pilling , tremie concrete |
Very High |
See 7.1.2 |
|
|
9.
Tool required for Slump cone test.
Tamping
Rod 16 MM Dia 600 MM
length.Metal Slump cone Top 100MM Bottom 200MM and Height 300MM
Metal scoop
Measuring Tape
Thermometer
Metal plate Tray
Timer Clock.